RocketRAID 3522
SATAII Host Adapter
User’s Guide
Revision: 1.0
Date: January 2008
HighPoint Technologies, Inc.
Przeglądanie stron 0
1 2 3 4 5 6 ... 69 70

Podsumowanie treści

Strona 1 - SATAII Host Adapter

RocketRAID 3522SATAII Host AdapterUser’s GuideRevision: 1.0Date: January 2008HighPoint Technologies, Inc.

Strona 2

Online RAID Level MigrationThis term describes the ability to change one type of array (RAID level), into a differenttype of array (changing a RAID 1

Strona 3 - Table of Content

Chapter 2RocketRAID 3522Hardware Description/InstallationContents of this Chapter:RocketRAID 3522 Hardware1 - RocketRAID 3522 Adapter Layout2 - Instal

Strona 4 - Table of Contents

RocketRAID 3522 Hardware Description/Installation2-1RocketRAID 3522 Hardware1 - RocketRAID 3522 Adapter LayoutPort1, Port2These represent the RocketRA

Strona 5 - Introduction

RocketRAID 3522 Hardware Description/Installation

Strona 6 - About this Guide

RocketRAID 3522 Hardware Description/Installation2-33 - Verifying InstallationOnce the RocketRAID 3522 host adapter and hard disks have been installed

Strona 7 - Advance RAID Features

RocketRAID 3522 Hardware Description/Installation

Strona 8 - PHYSICAL SPECIFICATIONS

Chapter 3RocketRAID 3522 BIOS UtilityContents of this Chapter:RocketRAID 3522 BIOS Utility1 - BIOS Command Overview2 - Disk Menu3 - Array Menu4 - Cont

Strona 9 - Array initialization

RocketRAID 3522 BIOS Utility3-1RocketRAID 3522

Strona 10 - Network Features

RocketRAID 3522 BIOS UtilityPress [ALT + S] to open the “System” menu in the figure 1; then select “Supervisormode”, and press ENTER. This will open t

Strona 11 - Chapter 2

RocketRAID 3522 BIOS Utility3-3Note: If the sel

Strona 12 - RocketRAID 3522 Hardware

CopyrightCopyright © 2008 HighPoint Technologies, Inc. This document contains materialsprotected by International Copyright Laws. All rights reserved.

Strona 13

RocketRAID 3522 BIOS UtilityNote: Variable Sector Size (VSS) for over 2TB support in 32bit LBA OS.It changes the sector size from default 512 Bytes to

Strona 14 - 3 - Verifying Installation

RocketRAID 3522 BIOS Utility3-5Start Task – sel

Strona 15 - 4 - Battery Backup

RocketRAID 3522 BIOS UtilityNetwork SettingUse this menu to configure the RocketRAID card’s network settings. Access theController menu, select “Netwo

Strona 16 - RocketRAID 3522 BIOS Utility

Chapter 4RocketRAID 3522 Driver andSoftware Installation Microsoft Windows(2000, XP, 2003 Server, Vista)Contents of this Chapter:Driver and Software C

Strona 17

RocketRAID 3522 Driver and Software InstallationDriver and Software CDThe RocketRAID 3522 retail box includes a Driver and Software CD.This CD can be

Strona 18 - 2 - Disk Menu

RocketRAID 3522 Driver and Software Installation4-25. Click on the “Please Selec

Strona 19 - 3 - Array Menu

RocketRAID 3522 Driver and Software Installation4-3Windows Driver InstallationBefore installing the RocketRAID 3522 device driver, make sure the Rocke

Strona 20 - View an Array

RocketRAID 3522 Driver and Software Installation4-4Installing the RocketRAID 352

Strona 21 - 4 - Controller Menu

4-5RocketRAID 3522 Driver and Software Installation5. When asked: “Would you like to install this driver software?”, select “Install”.6. Reboot the sy

Strona 22 - Network Setting

Chapter 5RocketRAID 3522Web RAID Management InterfaceContents of this Chapter: 1 - Web RAID Management Interface 2 - Preparing

Strona 23 - Chapter 4

Table of ContentsITable of ContentChapter 1IntroductionAbout this Guide ...

Strona 24 - Driver and Software CD

Web RAID Management Interface5-11 Web RAID Management InterfaceThere are two methods to access the RocketRAID 3522’s web-based RAID managementinterfac

Strona 25

Web RAID Management InterfaceThe in-band management software provides an access URL fo

Strona 26 - Windows Driver Installation

Web RAID Management Interface5-33) Checkmark each disk you wish to initialize, and click the Submit button.Warning: initializing disks may delete da

Strona 27

Web RAID Management Interface5-45. If you are creating a redundant RAID array (RAID1,

Strona 28 - Installation Verification

Web RAID Management Interface5-53) Click the Delete button.Note: An array in use by the operating system cannot be deleted. Any data stored ona delete

Strona 29 - Web RAID Management Interface

Web RAID Management Interface5-62) Highlight the desired RAID array3) Click the “Maint

Strona 30

Web RAID Management Interface 5-7An unexpected system crash may result in data loss while performing OCE/ORLM onan array. We strongly recommend backi

Strona 31 - 2 Preparing Hard disks

Web RAID Management Interface5-84 Device ManagementSelect the “Manage - Device” functi

Strona 32 - 3 Array Management

Web RAID Management Interface5-9User can also use the Web RAID management to upgrade controller’s firmware.SHI – Storage Health InspectorThe primary S

Strona 33 - Deleting an Array

Web RAID Management Interface5-10Device SSN#Serial number of the hard diskRAIDRAID/Non

Strona 34 - Verifying an Array

IIDriver and Software CD ...4-1Windows Driver Installation .

Strona 35

Web RAID Management Interface5-11Note: S.M.A.R.T attribute data is drive-specific. The software includes a list ofdefinitions for popular drive models

Strona 36 - Renaming an Array

Web RAID Management Interface5-12To rescan the devices:1) Select menu “Manage - Device

Strona 37 - 4 Device Management

Web RAID Management Interface5-136 Managing Events and TasksThe HighPoint Web RAID Management Software automatically logs all controllerrelated events

Strona 38

Web RAID Management Interface 5-14Scheduling a TaskTo add a task schedule:1) Select t

Strona 39

Web RAID Management Interface5-15Settings>SystemThe System Setting page include SAF-TE config file setting, Audible Alarm setting,Staggered Spinup

Strona 40

Web RAID Management Interface5-16Settings>UserThis setting allows you to alter the

Strona 41 - 5 Configuring Spare Disks

To test E-mail notification:1)Enter the necessary information for the recipient.2)Click the Test button.If the software is unable to send a test messa

Strona 42 - 6 Managing Events and Tasks

Chapter 6Linux Driver SupportContents of this Chapter:Fedora 7 Linux installation OverviewRed Hat Enterprise 5 OverviewSuSE Linux Enterprise Server (S

Strona 43 - 7 Settings

Linux Driver Support6-11 - Fedora 7 Linux installation OverviewThis section provides instructions describing how to install and utilize the RocketRAID

Strona 44

Linux Driver Support6-23 - Install

Strona 45

Chapter 1IntroductionContents of this Chapter:About this guideIntroducing the RocketRAID 3522 Host AdapterRocketRAID 3522 Features and SpecificationsU

Strona 46

Linux Driver Support6-3Then, instruct the system to load the module when booting. Use the followingcommands:#echo “modprobe hptiop” > /etc/init.d/h

Strona 47 - Linux Driver Support

Linux Driver Support6-41 - Red Hat

Strona 48 - Host Adapter

Linux Driver Support6-5Note:1. The system device mapping order is the same as the order shown in RocketRAIDBIOS Setting Utility. If no other SCSI adap

Strona 49

Linux Driver Support6-6Step 3 Conf

Strona 50 - 5 - Uninstalling the Driver

Linux Driver Support6-7Example:# gzip -dc /boot/initrd-xxx.img > /tmp/initrd.ext2# mkdir /mnt/initrd# mount -o loop /tmp/initrd.ext2 /mnt/initrd# c

Strona 51

Linux Driver Support6-81 - SuSE Li

Strona 52

Linux Driver Support6-9Additional Installation Notes:The system device mapping order is the same as the order shown in RocketRAIDhost adapter’s BIOS S

Strona 53

Linux Driver Support6-10# mount /d

Strona 54

6-112. Run the “depmod” command to update the module configuration:# depmod3. Next, run the “mkinitrd” command to update the initrd file:# mkinitrd4.

Strona 55 - Overview

Chapter 7FreeBSD Driver SupportContents of this Chapter:1 - Installing FreeBSD on the RocketRAID 3522 Controller2 - Installing the RocketRAID 3522 Dri

Strona 56

Introduction1-1About this GuideThe RocketRAID 3522 SATAII Host Adapter’s User’s Guide provides informationabout the functions and capabilities of the

Strona 57

FreeBSD Driver Support7-11 - Installing FreeBSD on the RocketRAID 3522 Con-trollerIf you would like to install FreeBSD onto arrays attached to the Roc

Strona 58

FreeBSD Driver Support7-2Booting [kern

Strona 59 - FreeBSD Driver Support

FreeBSD Driver Support7-3for FreeBSD 5.1-RELEASEok load disk0:hptiop-5.1.ko for FreeBSD 5.2.1-RELEASEok load disk0:hptiop-5.2.1.ko for FreeBSD

Strona 60

FreeBSD Driver Support7-47. Before exi

Strona 61 - <-press SPACE key

FreeBSD Driver Support7-5 For FreeBSD 5.x:# mdconfig –a –t vnode –f freebsd_5.x.img –u 0# mount /dev/md0 /mnt # cp /mnt/hptiop-xxx.ko /boot/kernel/h

Strona 62

FreeBSD Driver Support7-6Note: If you

Strona 63 - Step 1 Copy the Driver Module

Chapter 8 Mac OSX DriverContents of this Chapter: Installing the driver and RAID utility

Strona 64 - <-press SPACE key

Mac OSX Driver1 Installing the driver and RAID utilityInstalling the package1) Double click the package labeled “rr3xxx_4xxx-MacOSX-universal-vxxx.dmg

Strona 66 - Chapter 8

Customer SupportIf you encounter any problems while utilizing the RocketRAID 3522, or have anyquestions about this or any other HighPoint product, fee

Strona 67

Introduction1-2On

Strona 68 - Customer Support

FCC Part 15 Class B Radio Frequency Interference statementThis equipment has been tested and found to comply with the limits for a Class Bdigital devi

Strona 69

Introduction1-3Array Monitors, Alerts and Indicators• SMTP for email notification• Alarm / Buzzer alerts for array activity• SAF-TE support•

Strona 70

Introduction1-4El

Komentarze do niniejszej Instrukcji